2. Prevent demagnetization (1) Magnetic moment can not be designed too small. (2) It should be run under the specified temperature, the medium temperature is strictly not allowed. A platinum resistance temperature sensor can be installed on the outer surface of the magnetic pump isolation sleeve to detect the temperature rise in the annulus area so as to alarm or stop when the temperature exceeds the limit 3. Prevent dry friction (1) Do not idle. (2) It is forbidden to use the medium to empty. (3) In the case of the outlet valve is closed, the pump continuous operation time shall not exceed 2min, to prevent the magnetic actuator from overheating failure.