Flow is insufficient CQB-F-type fluorine-lined magnetic pump one of the common failures, then when the pump encountered such a failure, we know where the reason? And what should be done to solve the problem If you are interested in these issues, the following is about the CQB-F lining fluorine magnetic pump flow reasons and troubleshooting methods introduced. CQB-F lined fluorine magnetic pump causes of flow and troubleshooting a, CQB-F Lined fluorine magnetic pump flow reasons 1, suction diameter is too small; 2, the impeller flow blockage; 3, lift is too high; 4, the speed is too low; 5, the impeller wear or corrosion serious; 6, the installation of the total head too high or too much suction; 7, suction pipe air leaks; 8, seal ring serious wear and tear. Second, the CQB-F lining fluorine magnetic pump insufficient flow of exclusion 1, reconcile the inlet pipe; 2, cleaning the impeller; 3, open the large valve; 4, to restore the rated head; 5, replace the impeller; Pump installation position; 7, refused to leak; 8, replace the seal ring. Read more: China Building Water Exhibition Pump Valve Tube Fittings Exhibition Water Expo Xiamen Maritime Exhibition Internet + Forum Yiwu Expo Industry Interconnection (Xiamen) Technology Co., Ltd. Asia Pump Network Editor: He Duanhui (QQ / WeChat:) http://beng
.liuti.cn/ (service hotline:)
Steel Plates
Steel Plates,Steel Sheet Pile,Steel Sheet Pipe Pile
Huilifeng Anti-Corrosion And Insulation Steel Pipe Group Co., Ltd , http://www.tj-steeltube.com
没有评论:
发表评论