| Fault: can not reach the design flow | |
| the reason: | method: | 
| 1. There is air inhalation | 1. Check the temple ┢ lesson ⑴ ﹝ cowardice / span> | 
| 2. As the water level decreases, the submergence depth is not enough, | 2. Extend the suction pipe to deepen the depth of flooding | 
| 3. Impeller clogged with foreign body | 3. Remove and remove foreign objects | 
| 4. Rotor part of the serious wear and tear | 4. replace the seal bad | 
| Fault: pump consumes too much power | |
| the reason: | method: | 
| 1. The packing is too tight and heats up | 1. Appropriate to relax | 
| 2. Flow too large | Off gate valve opening | 
| 3. Swivel body and shell have rub | 3. repair whole | 
| 4. Pump bearing wear | 4. Replace the bearing | 
| 5 pump shaft bending | Replace or correct | 
| Fault: pump vibration increased | |
| the reason: | method: | 
| 1. Impeller partially blocked | 1. Remove and remove foreign material | 
| Impeller damaged | 2. More change | 
| 3. Flow is too small | 3. Slightly open the outlet valve | 
| 4. Shaft and motor do not mind | 4. Fixed point to find correct | 
| Bearing damage | 5. More change | 
| 6. Mixed with air. Cavitation occurs | 6. Change the suction position. Improve the suction pipe | 
| Fault: pressure gauge pressure but still no water | |
| the reason: | method: | 
| 1. Outlet resistance is too large | 1. Check the hiss tick Oh trip ?? / span> | 
| 2. The direction of rotation is wrong | 2. Check? Say? Two mutual transfer | 
| 3. The outlet pipe valve is not open | 3. Open the outlet valve | 
| Impeller clogged | 4. Remove impeller dirt | 
| Fault: pump does not absorb water pressure gauge and vacuum gauge pointer violently beating | |
| the reason: | method: | 
| 1. Perfusion is not enough water | 1. Check if the foot valve is leaking | 
| 2. Piping and instrumentation joints leak | 2. Tighten the leak | 
| 3. Suction is too high | Reduce the water absorption height | 
| Fault: pump is not suction vacuum table indicates a high degree of vacuum | |
| the reason: | method: | 
| 1. The bottom valve is not open or blocked | 1. Check that chase? / Span> | 
| 2. Suction pipe resistance is too large | 2. Change the water absorption | 
| The filter is clogged | 3. Clean the filter | 