Fault: can not reach the design flow | |
the reason: | method: |
1. There is air inhalation | 1. Check the temple ┢ lesson ⑴ ﹝ cowardice / span> |
2. As the water level decreases, the submergence depth is not enough, | 2. Extend the suction pipe to deepen the depth of flooding |
3. Impeller clogged with foreign body | 3. Remove and remove foreign objects |
4. Rotor part of the serious wear and tear | 4. replace the seal bad |
Fault: pump consumes too much power | |
the reason: | method: |
1. The packing is too tight and heats up | 1. Appropriate to relax |
2. Flow too large | Off gate valve opening |
3. Swivel body and shell have rub | 3. repair whole |
4. Pump bearing wear | 4. Replace the bearing |
5 pump shaft bending | Replace or correct |
Fault: pump vibration increased | |
the reason: | method: |
1. Impeller partially blocked | 1. Remove and remove foreign material |
Impeller damaged | 2. More change |
3. Flow is too small | 3. Slightly open the outlet valve |
4. Shaft and motor do not mind | 4. Fixed point to find correct |
Bearing damage | 5. More change |
6. Mixed with air. Cavitation occurs | 6. Change the suction position. Improve the suction pipe |
Fault: pressure gauge pressure but still no water | |
the reason: | method: |
1. Outlet resistance is too large | 1. Check the hiss tick Oh trip ?? / span> |
2. The direction of rotation is wrong | 2. Check? Say? Two mutual transfer |
3. The outlet pipe valve is not open | 3. Open the outlet valve |
Impeller clogged | 4. Remove impeller dirt |
Fault: pump does not absorb water pressure gauge and vacuum gauge pointer violently beating | |
the reason: | method: |
1. Perfusion is not enough water | 1. Check if the foot valve is leaking |
2. Piping and instrumentation joints leak | 2. Tighten the leak |
3. Suction is too high | Reduce the water absorption height |
Fault: pump is not suction vacuum table indicates a high degree of vacuum | |
the reason: | method: |
1. The bottom valve is not open or blocked | 1. Check that chase? / Span> |
2. Suction pipe resistance is too large | 2. Change the water absorption |
The filter is clogged | 3. Clean the filter |